Low voltage reactive power compensation controller
Product Description
The low-voltage reactive power compensation controller is used in conjunction with the NA series of intelligent switching switches, which can collect and display electrical measurement data, monitor and display the operating conditions and switching status of the intelligent switching switches, and automatically control according to reactive power and target power factor Switching capacitors and other functions....More
Performance Characteristics
The low-voltage reactive power compensation controller is connected to the NA series intelligent switching switch through the level line or the RJ45 communication line; the controller collects the grid electrical measurement data, and while displaying the operation status of the intelligent switching switch, it can directly based on the current electrical measurement data, Intelligent switching control of the capacitor bank to achieve the effect of reactive power compensation. ... More
The Main Function

(1 )  Setting Function 

          Set current transformation ratio, target power factor, switching threshold, switching delay, capacitor configuration, harmonic voltage total distortion rate protection setting, harmonic current total distortion rate protection setting, communication parameters, etc. 

          The setting parameters are automatically saved and will not be lost after power failure.

(2 )  Reactive power compensation function 

         The sampled physical quantity is reactive power, with high compensation accuracy and no switching oscillation. 

         It has two operating modes: manual switching and automatic switching. 

         Logic switching mode, the capacitance of each group can be set freely. 

         The control output can be adapted to switching components such as electronic switches, composite electronic switches or synchronous switching switches. 

         Control output contacts 1-16 (24) channels, each DC 12V 20mA. 

(3 )  Protective function 

         It has protection functions such as phase loss, undervoltage, overvoltage, and over-harmonics.

(4 )  Communication function 

         It has RS485 data transmission interface and supports MODBUS communication protocol. Through its connection with a computer/meter reading machine or terminal and other upper computers, it can detect the relevant parameters of the power grid in real time, set parameters, and work.

Make a pleadingIt can modify the preset parameters and realize the collection and exchange of various data information locally or remotely. 

Selection Table

Serial Number

Product Number

Product Description

Supporting Switching Switch Model

1

JKWNA-9L16

16Road level control, no remote communication口

   NA-700□□/380D-30/40        NA-700□□/380J-30/40

2

JKWNA-9L16R

16Channel level control with remote communication口

   NA-700□□/380D-30/40         NA-700□□/380J-30/40

3

JKWNA-9L24

24Road level control, no remote communication口

  NA-700□□/380D-30/40    NA-700□□/380J-30/40

4

JKWNA-9L24R

24Channel level control with remote communication口

  NA-700□□/380D-30/40     NA-700□□/380J-30/40

5

JKWNA-9

RJ45Network control, no remote communication口

           NA-700□□/380R-30/40

6

JKWNA-9R

RJ45Networking control, with remote communication口

           NA-700□□/380R-30/40

weChat public account
Address: No. 519-1, Chengxin Avenue, Jiangning District, Nanjing      Sales Hotline/Transfer Value:(025)58531222/58531223 Customer Hotline:400-880-9936      Postcode:211102      Mailbox:sales@jsna.cn      Record number: Su ICP No.19063063-1 Copyright ©2018 JIANGSU NICETOWN INTELLIGENT ENERGY CO.,LTD. All Rights Reserved